Home > Technical Support > Solid-State Array LiDAR CE30-C > Q: Can CE 30 -C be used outdoors? Why are the results in the outdoor test inconsistent with the parameters in the specification?

Q: Can CE 30 -C be used outdoors? Why are the results in the outdoor test inconsistent with the parameters in the specification?

A: CE 30-C can detect objects outdoors, but the near-field dead zone will increase and the error will increase. For details, please refer to " DE-LiDAR CE30-C Datasheet ": 6. Outdoor Use. The parameters provided in the CE 30-C specification are the test results in the dark room, and they are also applicable in general indoor conditions. For the test conditions, see the " DE-LiDAR CE30-C Operation Manual ": 2. Accuracy test instructions

Prev:Q: We only care about the situation in a certain area of the field of view. Can I set the area of interest?

Next:No Data


Support Email